浏览全部资源
扫码关注微信
1. 中核武汉核电运行技术股份有限公司
2. 中核核电运行管理有限公司二厂
3. 中核集团三门核电有限公司
纸质出版日期:2013
移动端阅览
[1]施少波,张维,栾兴峰,孙玉.核电厂二回路管道FAC壁厚减薄强度评定方法[J].核技术,2013,36(04):290-294.
SHI Shaobo1 ZHNANG Wei2 LUAN Xingfeng2 SUN Yu3 1. Assessment method of secondary loop pipe wall thinning due to flow accelerated corrosion in nuclear power plants[J]. Nuclear techniques, 2013, 36(4): 040655
[1]施少波,张维,栾兴峰,孙玉.核电厂二回路管道FAC壁厚减薄强度评定方法[J].核技术,2013,36(04):290-294. DOI: 10.11889/j.0253-3219.2013.hjs.36.040655.
SHI Shaobo1 ZHNANG Wei2 LUAN Xingfeng2 SUN Yu3 1. Assessment method of secondary loop pipe wall thinning due to flow accelerated corrosion in nuclear power plants[J]. Nuclear techniques, 2013, 36(4): 040655 DOI: 10.11889/j.0253-3219.2013.hjs.36.040655.
FAC造成二回路管道的壁厚减薄
致使管道的强度降低
当管道减薄到一定程度时
管道会发生破裂
容易引起严重的安全事故。本文针对管道FAC壁厚减薄问题
建立了完整的分析评定路线。重点介绍以API579指导实现的壁厚减薄Level 3评定方法:利用有限元软件ANSYS的APDL参数化建模功能
建立了直管、弯头、大小头的参数化模型
该方法可方便定义管道的几何参数和材料参数、管端载荷和约束
通过直接调用在役检测的壁厚检测数据
自动建立管道的FAC壁厚减薄的真实壁厚模型。并利用极限载荷法评定壁厚减薄管道的强度
实现了API579壁厚减薄体积型缺陷的Level 3评定。
Background: Flow Accelerated Corrosion(FAC) leads to wall thinning(metal lose) and strength reduction of steel piping.Piping degradation due to FAC can affect plant reliability and may cause serious accident.Purpose: This paper sets up the analysis and assessment method for the wall thinning due to FAC.Methods: This method mainly bases on local metal loss Level 3 of API 579.Using FEA software ANSYS develop parameterized models
including straight pipe
elbow
reducer
etc.The models can be expediently defined geometry and material parameter
load and constraint condition.Furthermore
the real thickness model of the pipe can be established by using the data of in-service inspection.Results: With the limit-load analysis method to assessment the strength of piping
the method achieved local metal loss Level 3 assessment effectively.Conclusions: Using this method to establish the true model of pipe wall thickness
can improve the accuracy of analysis of pipe wall thickness thinning evaluation.
0
浏览量
110
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构