浏览全部资源
扫码关注微信
1.中国科学院上海应用物理研究所 张江园区 上海 201204
2.中国科学院大学 北京 100049
[ "王建军, 男, 1991年出生, 2014年毕业于湘潭大学, 现为硕士研究生, 研究领域为移相器方向", "WANG Jianjun, male, born in 1991, graduated from Xiangtan University in 2014, master student, focusing on phase shifter technology" ]
周巧根, E-mail:zhouqiaogen@sinap.ac.cn ZHOU Qiaogen, E-mail:zhouqiaogen@sinap.ac.cn
收稿日期:2017-03-03,
修回日期:2017-03-29,
纸质出版日期:2017-07-10
移动端阅览
王建军, 张伟, 周巧根. 上海软X射线装置中纯永磁移相器的积分场垫补[J]. 核技术, 2017,40(7):070102
Jianjun WANG, Wei ZHANG, Qiaogen ZHOU. Integral field shimming for pure permanent magnet phase shifter in SXFEL[J]. Nuclear techniques, 2017, 40(7): 070102
王建军, 张伟, 周巧根. 上海软X射线装置中纯永磁移相器的积分场垫补[J]. 核技术, 2017,40(7):070102 DOI: 10.11889/j.0253-3219.2017.hjs.40.070102.
Jianjun WANG, Wei ZHANG, Qiaogen ZHOU. Integral field shimming for pure permanent magnet phase shifter in SXFEL[J]. Nuclear techniques, 2017, 40(7): 070102 DOI: 10.11889/j.0253-3219.2017.hjs.40.070102.
X射线自由电子激光(Free-electron Laser
FEL)达到饱和功率输出时所需要的波荡器总长度为数十米甚至上百米,目前国内外研制的波荡器只能分段加工,且每段长度一般在5m以内。为了保证两相邻波荡器间辐射光的相位相互匹配,通用的设计是在相邻波荡器之间增加移相器。移相器的加入不应对电子束流产生影响,其产生的磁场沿束流方向的一二次积分必须达到技术要求。由于移相器较短,二次积分较小,可不予考虑。在不考虑永磁块非线性的基础上,导出了纯永磁移相器的磁场一次积分以及调整移相器中某些磁化块的高度和倾斜角度产生的磁场一次积分变化量的解析表达式。利用这种方法对上海软X射线自由电子激光装置中的5台移相器做积分场垫补,使得每台移相器的磁场一次积分在好场区内都小于20Gs·cm,满足工程设计要求。
Background
2
As one of the most important equipment in free-electron lasers (FEL)
undulator system is as long as tens meters or even hundreds meters. Due to the industrial technical constraints of the undulator manufacture
undulator system has to be segmented by 5-m length. In order to ensure that the phase of the radiation field between two adjacent undulators is matched with each other
conventionally
phase shifter components are inserted between the adjacent undulators.
Purpose
2
This study aims to minimize the integral field error of the phase shifter for undulator linkage.
Methods
2
Based on the factor that the nonlinearity of pure permanent magnet can be ignored
the first order integral term of magnet field is derivated. By shimming the height and tilt angle of vertically magnetization block in the phase shifter
its integral error can be reduced. Finally
a two-dimensional high-precision Hall probe is used in the experiment to measure the integral error of the phase shifter in different magnetic gaps.
Results
2
After field correction
the integral error of the phase shifter is less than 20 Gs·cm both in the center line for all gaps and horizontal position x less than 2 mm at the minimum gap.
Conclusion
2
This method has been applied for all the 6 phase shifters that satisfy engineering design requirements in Shanghai soft X-ray free electron laser (SXFEL).
赵振堂. X射线自由电子激光试验装置初步设计报告[R]. 上海: 中国科学院上海应用物理研究所, 2014.
ZHAO Zhentang. Preliminary design report of X-ray free electron laser test device[R]. Shanghai: Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2014.
Diviacco B, Ferrando O, Tosi L, et al. Operational aspects of elliptical undulators at ELETTRA[R]. Shanghai: 25th ICFA Advanced Beam Dynamics Workshop (SSILS), 2001.
Ganter R. Swiss FEL phase matcher specifications[R]. Swiss: Paul Scherrer Institute, 2012.
郭 硕鸿 . 电动力学 , : 北京 高等教育出版社 , 2008 . 10 - 15 .
Shuohong GUO . Electrodynamics , : Beijing Higher Education Press , 2008 . 10 - 15 .
周巧根. 均匀磁化永磁块的磁化强度误差对磁场及其一二次积分的影响[R]. 上海: 中国科学院上海应用物理研究所, 2008.
ZHOU Qiaogen. Influence of magnetization error of uniform magnetized permanent magnets on magnetic field and its first or second integral[R]. Shanghai: Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2008.